Microprocessor Based Controls for Programmable Ventilation
Optimize your ventilation system with the Airetrak™ microprocessor based control system. It is engineered to give ventilation system designers
and installers the versatility required to balance ventilation with energy conservation while maintaining indoor air quality. It is ideal for use with any ventilation system where specific
ventilation rates are required. The Airetrak is often used to control a bathroom fan employed as a whole house ventilation system. It will quietly cycle the fan on and off, at preset times,
throughout the day and or night.

Airetrak™ |
|
 |
On site programming takes less than two minutes. Installation is a snap. The Airetrak fits into a single gang electrical box and utilizes a standard
cover plate. Once installed, the Airetrak automatically controls the fan speed and cycle time, while allowing the occupant access to a full speed boost cycle. The battery circuit ensures
proper system operation, even after a power failure.
Features
Air Flow: Rate is adjustable from 40% to 100% of fan capacity. The installer can select from 16 different settings based on home
size, occupancy and other field conditions.
Built-in Timer: Programmed on installation to operate the ventilation equipment in 5 minute increments (5,10,15, etc.) during a 12
or 24 hour cycle.
Boost Feature: To activate the boost feature, simply press the BOOST button and the fan will operate at full speed for 20 minutes
then automatically return to its programmed cycle.
Simple timer mode: The system can be set to a "0" programmed cycle operation, at which point it becomes a silent, 20 minute timer.
Also available, is the Airetrak™CD. The AiretrakCD (constant duty) is used to control a bathroom fan when constant, low speed fan flow is desirable. Pushing the BOOST
button causes the fan to run continuously at full speed until the button is pushed again.
Learn how Tamarack has worked with Next Gen, Erie-Ellington Homes and GrowHome to provide three remarkably different
solutions to the same housing problem. Links to case studies provided.
Key Benefits
- Easy Installation
- Energy Efficient
- Automatic
- Invisible
- Built In "Real-Time" Timer
- Front Panel, Full Speed Override
- Fits In Single Gang Work Box
- Economical
- UL/CUL Listed
- One Year Warranty
|
Location
The Airetrak control is installed in the room where the fan to be controlled is located. |
Specifications
| |
Airetrak™ |
Airetrak™CD |
| Housing Size |
►3.625" x 1.625" x 1" |
►3.625" x 1.625" x 1" |
| Input |
►120 VAC 60 Hz |
►120
VAC 60 Hz | | Output |
►120 VAC 60 Hz |
►120 VAC 60 Hz |
| Maximum Load |
►180 watts |
►180 watts |
| Switching |
►SPST |
►SPST |
| Program Protection |
►Lithium battery backup Rated 400 hrs |
►Not required |
| Timer |
►12 or 24 hr operation, 0-60 min duty cycle |
►24 hr constant operation |
|
Speed Control |
►40-100% of rated fan speed, Soft start motor control |
►40-100% of rated fan speed, Soft start
motor control |
| Override |
►Indicator light Front panel actuator Manual shutoff 20 minute auto-shutoff |
►Indicator light Front panel actuator Manual shutoff |
|